Quantification of irinotecan, SN38, and SN38G in human and porcine plasma by ultra high-performance liquid chromatography-tandem mass spectrometry and its application to hepatic chemoembolization

  1. Author:
    Chen, X. H.
    Peer, C. J.
    Alfaro, R.
    Tian, T.
    Spencer, S. D.
    Figg, W. D.
  2. Author Address

    [Figg, William D.] NCI, Clin Pharmacol Program, NIH, Ctr Canc Res, Bethesda, MD 20892 USA. [Chen, Xiaohong; Spencer, Shawn D.] NCI, Clin Pharmacol Program, SAIC Frederick Inc, Frederick, MD 21702 USA. [Alfaro, Raul] NIH, Pharm Sect, Ctr Clin, Bethesda, MD 20892 USA.;Figg, WD (reprint author), NCI, Clin Pharmacol Program, NIH, Ctr Canc Res, 9000 Rockville Pike,Bldg 10,Room 5A01, Bethesda, MD 20892 USA;wdfigg@helix.nih.gov
    1. Year: 2012
    2. Date: Mar
  1. Journal: Journal of Pharmaceutical and Biomedical Analysis
    1. 62
    2. Pages: 140-148
  2. Type of Article: Article
  3. ISSN: 0731-7085
  1. Abstract:

    An analytical method was developed and validated for the quantitative determination of irinotecan, its active metabolite SN38, and glucuronidated SN38 (SN38-G) in both porcine and human plasma. Calibration curves were linear within the concentration range of 0.5-100 ng/mL for SN38 and SN38-G, and 5-1000 ng/mL for irinotecan. Sample pretreatment involved solid-phase extraction of 0.1 mL aliquots of plasma. Irinotecan, SN38, SN38-G, and the internal standards, irinotecan-d10, tolbutamide, and camptothecin, respectively, were separated on a Waters ACQUITY UPLC (TM) BEH RP18 column (2.1 mm x 50 mm, 1.7 mu m), using a mobile phase composed of methanol and 0.1% formic acid. Accuracy of quality control samples in human plasma ranged from 98.5 to 110.3%, 99.5 to 101.7% and 96.2 to 98.9% for irinotecan, SN38, and SN38-G, respectively. Precision of the three analytes in the same order ranged from 0.8 to 2.8%, 2.4 to 5.7%, and 2.4 to 2.8%. All three analytes proved stable in plasma through four freeze/thaw cycles, as well as through 6 h in whole blood at room temperature. The method was likewise validated in porcine plasma with comparable accuracies and precisions also within the generally acceptable range. The validated method was applied to both preclinical and clinical trials involving hepatic chemoembolization of irinotecan drug-eluting beads to study the pharmacokinetics of the three analytes. Published by Elsevier B.V.

    See More

External Sources

  1. DOI: 10.1016/j.jpba.2012.01.008
  2. WOS: 000301032200018

Library Notes

  1. Fiscal Year: FY2011-2012
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel