Skip NavigationSkip to Content

Derivatization of peptides and small proteins for improved identification and detection in capillary zone electrophoresis (CZE)

  1. Author:
    Liu, H. J.
    Cho, B. Y.
    Strong, R.
    Krull, I. S.
    Cohen, S.
    Chan, K. C.
    Issaq, H. J.
  2. Author Address

    Krull IS Northeastern Univ, Dept Chem 102 Hurtig Bldg,360 Huntington Ave Boston, MA 02115 USA Northeastern Univ, Dept Chem Boston, MA 02115 USA Waters Corp, Biotechnol Appl Lab Milford, MA 01757 USA NCI, Frederick Canc Res & Dev Ctr, SAIC Frederick Frederick, MD 21702 USA
    1. Year: 1999
  1. Journal: Analytica Chimica Acta
    1. 400
    2. Special Issue SI
    3. Pages: 181-209
  2. Type of Article: Article
  1. Abstract:

    Peptides and small proteins, of limited molecular weight (MW) can be derivatized with a 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (6-AQC) reagent, leading to a single capillary zone electrophoresis (CZE) peak, suggestive of a completely tagged product. The number of tags per molecule was demonstrated by matrix assisted, laser desorption, time-of-flight mass spectrometry (MALDI-TOFMS) studies. In CZE, these species have greatly improved plate count and peak shape, improved (lowered) detectabilities, and in general, improved identification properties in the CZE mode in high performance capillary electrophoresis (HPCE). The formation of what appears to be a single, homogeneously tagged product is a function of how the derivatizations are performed. Once these conditions are optimized, virtually all peptides and small proteins tested (limited MW) can form single, fully tagged products, with the desirable CZE properties. These derivatization approaches thus lead to products that perform and are detected much better in CZE than their precursors (native, untagged peptides). The determined plate counts for these tagged peptides were as high as 6 million plates/m, which was very reproducible, and 59-12,000 times higher than the untagged (native) molecules. The peak symmetry was also improved greatly. The limit of detection (LOD) of some tested 6-AQC tagged peptides were nine to 209 times improved (lower) with ultraviolet (UV) absorption detection, again as compared with that for the native species. The LOD could be further lowered via laser induced fluorescence (LIF) detection in CZE, especially when acetonitrile (ACN) containing buffers were used. (C) 1999 Elsevier Science B.V. All rights reserved. [References: 71]

    See More

External Sources

  1. No sources found.

Library Notes

  1. No notes added.
NCI at FrederickClose Button

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel