Skip NavigationSkip to Content

A Multiplexed Real-Time PCR Assay for Simultaneous Quantification of Human Immunodeficiency Virus and Hepatitis B Virus for Low-And-Middle- Income Countries

  1. Author:
    Bocar, Fofana Djeneba
    Aminatou, Coulibaly
    Mamoudou, Maiga
    Nguyen,Thuy
    Joel, Gozlan
    Zoumana, Diarra
    Amadou, Koné
    Yacouba, Cissoko
    Issiaka, Maiga Almoustapha
    Claudia, Hawkins A
    Robert, Murphy L
    Morand-Joubert, Laurence
    Mahamadou, Diakité
    Jane, Holl L
    Sally, McFall M
  2. Author Address

    1Faculty of Medicine, University of Sciences, Techniques and Technologies of Bamako (USTTB), Bamako BP 1805, Mali. Electronic address: djesfof@gmail.com. 2University Clinical Research Center, International Centers for Excellence in Research (UCRC), University of Sciences, Techniques and Technologies of Bamako, Bamako, Mali. 3Institute for Global Health, Northwestern University, Chicago, IL 60208, USA. 4Clinical Retrovirology Section, HIV Dynamics and Replication Program, National Cancer Institute, Frederick, MD, USA. 5Sorbonne Université, INSERM, Institut Pierre Louis d'Epidémiologie et de Santé Publique (iPLESP), for Department of Virology, Assistance Publique-Hôpitaux de Paris (AP-HP), Saint-Antoine Hospital, Paris F-75012, France. 6Faculty of Medicine, University of Sciences, Techniques and Technologies of Bamako (USTTB), Bamako BP 1805, Mali. 7Biological Sciences Division University of Chicago, IL 60637, USA.
    1. Year: 2024
    2. Date: Sep 02
    3. Epub Date: 2024 09 02
  1. Journal: Journal of Virological Methods
    1. 330
    2. Pages: 115026
  2. Type of Article: Article
  3. Article Number: 115026
  1. Abstract:

    Due to shared routes of transmission, including sexual contact and vertical transmission, HIV-HBV co-infection is common, particularly in sub-Saharan Africa. Measurement of viral load (VL), for both HIV and HBV, plays a critical role for determining their infectious phase and monitoring response to antiviral therapy. Implementation of viral load testing in clinical settings is a significant challenge in resource-limited countries, notably because of cost and availability issues. We designed HIV and HBV primers for conserved regions of the HIV and HBV genomes that were specifically adapted to viral strains circulating in West Africa that are HIV-1 subtype CRF02AG and HBV genotype E. We first validated two monoplex qPCR assays for individual quantification and, then developed a multiplex qPCR for simultaneous quantification of both viruses. HIV RNA and HBV DNA amplification was performed in a single tube using a one-step reverse transcription-PCR reaction with primers and probes targeting both viruses. Performance characteristics such as the quantification range, sensitivity, and specificity of this multiplex qPCR assay were compared to reference qPCR tests for both HIV and HBV viral load quantification. The multiplex assay was validated using clinical samples from co- or mono-infected patients and gave comparable viral load quantification to the HIV and HBV reference test respectively. The multiplex qPCR demonstrated an overall sensitivity of 71.25% [68.16-74.3] for HBV and 82% [78.09-85.90] for HIV and an overall specificity of 100% [94.95-100] for both viruses. Although the overall sensitivities of the HIV and HBV assays were lower than the commercial comparator assays, the sensitivity in the clinical decision range of >1000 copies/mL for HIV was 80% [71.26-88.73] and >1000 IU/mL for HBV was 100% [95.51-100] which indicates the test results can be used to guide treatment decisions. This in-house developed multiplex qPCR assay represents a useful diagnostic tool as it can be performed on affordable "open" real-time PCR platforms currently used for HIV or SARS-Cov-2 infection surveillance in Mali. Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.

    See More

External Sources

  1. DOI: 10.1016/j.jviromet.2024.115026
  2. PMID: 39233060
  3. PII : S0166-0934(24)00150-2

Library Notes

  1. Fiscal Year: FY2024-2025
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel