Skip NavigationSkip to Content

A fluorescence-based high-throughput screening assay for inhibitors of human immunodeficiency virus-1 reverse transcriptase-associated ribonuclease H activity

  1. Author:
    Parniak, M. A.
    Min, K. L.
    Budihas, S. R.
    Le Grice, S. F. J.
    Beutler, J. A.
  2. Author Address

    Univ Pittsburgh, Dept Med, 930 Scaife Hall, Pittsburgh, PA 15261 USA Univ Pittsburgh, Dept Med, Pittsburgh, PA 15261 USA McGill Univ, Dept Chem, Montreal, PQ H3A 2T5, Canada NCI, HIV Drug Resistance Program, Frederick, MD 21701 USA NCI, Mol Targets Dev Program, Frederick, MD 21701 USA Parniak MA Univ Pittsburgh, Dept Med, 930 Scaife Hall, Pittsburgh, PA 15261 USA
    1. Year: 2003
  1. Journal: Analytical Biochemistry
    1. 322
    2. 1
    3. Pages: 33-39
  2. Type of Article: Article
  1. Abstract:

    A fluorescence resonance energy transfer assay readily applicable to 96-well and 384-well microplate formats with robotic operation was developed to enable high-throughput screening for inhibitors of human immunodeficiency virus-1 (HIV-1) reverse transcriptase (RT)-associated RNase H activity, an underexplored target for antiretroviral development. The assay substrate is an 18-nucleotide 3'-fluorescein-labeled RNA annealed to a complementary 18-nucleotide 5'-Dabcyl- modified DNA. The intact duplex has an extremely low background fluorescent signal and provides up to 50-fold fluorescent signal enhancement following hydrolysis. The size and sequence of the duplex are such that HIV-1 RT-RNase H cuts the RNA strand close to the 3' end. The fluorescein-labeled ribonucleotide fragment readily dissociates from the complementary DNA at room temperature with immediate generation of a fluorescent signal. This assay is rapid, inexpensive, and robust, providing Z' factors of 0.8 and coefficients of variation of about 5%. The assay can be carried out both in real-time (continuous) and in "quench" modes; the latter requires only two addition steps with no washing and is thus suitable for robotic operation. Several chemical libraries totaling more than 106,000 compounds were screened with this assay in approximately 1 month. (C) 2003 Elsevier Inc. All rights reserved.

    See More

External Sources

  1. No sources found.

Library Notes

  1. No notes added.
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel