Skip NavigationSkip to Content

Effects of electron-beam irradiation on whole genome amplification

  1. Author:
    Bergen, A. W.
    Qi, Y.
    Haque, K. A.
    Welch, R. A.
    Garcia-Closas, M.
    Chanock, S. J.
    Vaught, J.
    Castle, P. E.
  2. Author Address

    NCI, Div Canc Epidemiol & Genet, Bethesda, MD 20892 USA. NCI, Core Genotyping Facil, Ctr Adv Technol, Gaithersburg, MD USA. NCI, Frederick Canc Res & Dev Ctr, Intramural Res Support Program, Sci Applicat Int Corp, Frederick, MD USA. NCI, Canc Res Ctr, Pediat Oncol Branch, Bethesda, MD USA Bergen, AW, NCI, Div Canc Epidemiol & Genet, 6120 Execut Blvd, Bethesda, MD 20892 USA
    1. Year: 2005
    2. Date: APR
  1. Journal: Cancer Epidemiology Biomarkers & Prevention
    1. 14
    2. 4
    3. Pages: 1016-1019
  2. Type of Article: Article
  1. Abstract:

    Electron-beam (E-beam) irradiation, currently being used to sterilize mail addressed to selected ZIP codes in the United States, has significant negative effects on the genomic integrity of DNA extracted from buccal-cell washes. We investigated the yield, composition, and genotyping performance of whole genome amplified DNA (wgaDNA) derived from 24 matched samples of E-beam-irradiated and nonirradiated genomic DNA (gDNA) as a model for the effects of degraded gDNA on the performance of whole genome amplification. gDNA was amplified using the Multiple Displacement Amplification method. Three methods of DNA quantification analysis were used to estimate the yield and composition of wgaDNA, and 65 short tandem repeat and single nucleotide polymorphism genotyping assays were used to evaluate the genotyping performance of irradiated and nonirradiated gDNA and wgaDNA. Compared with wgaDNA derived from nonirradiated gDNA, wgaDNA derived from irradiated gDNA exhibited a significantly reduced yield of wgaDNA and significantly reduced short tandem repeat and single nucleotide polymorphism genotyping completion and concordance rates (P < 0.0001). Increasing the amount of irradiated gDNA input into whole genome amplification improved genotyping performance of wgaDNA but not to the level of wgaDNA derived from nonirradiated gDNA. Multiple Displacement Amplification wgaDNA derived from E-beam-irradiated gDNA is not suitable for genotyping analysis

    See More

External Sources

  1. WOS: 000228351300044

Library Notes

  1. No notes added.
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel