Energy dispersive X-ray analysis of titanium dioxide nanoparticle distribution after intravenous and subcutaneous injection in mice

  1. Author:
    Patri, A.
    Umbreit, T.
    Zheng, J.
    Nagashima, K.
    Goering, P.
    Francke-Carroll, S.
    Gordon, E.
    Weaver, J.
    Miller, T.
    Sadrieh, N.
    McNeil, S.
    Stratmeyer, M.
  2. Author Address

    Nanotechnology Characterization Laboratory, SAIC-Frederick Inc., NCI-Frederick, Frederick, Maryland 21702, USA.
    1. Year: 2009
    2. Date: Nov
    3. Epub Date: 7/25/2009
  1. Journal: Journal of applied toxicology : JAT
    1. 29
    2. 8
    3. Pages: 662-72
  2. Type of Article: Article
  3. ISSN: 1099-1263 (Electronic);0260-437X (Linking)
  1. Abstract:

    In an effort to understand the disposition and toxicokinetics of nanoscale materials, we used EDS (energy dispersive X-ray spectroscopy) to detect and map the distribution of titanium dioxide (TiO2) in tissue sections from mice following either subcutaneous (s.c.) or intravenous (i.v.) injection. TiO2 nanoparticles were administered at a dose of 560 mg/kg (i.v.) or 5600 mg/kg (s.c.) to Balb/c female mice on two consecutive days. Tissues (liver, kidney, lung, heart, spleen, and brain) were examined by light microscopy, TEM (transmission electron microscopy), SEM (scanning electron microscopy), and EDS following necropsy one day after treatment. Particle agglomerates were detected by light microscopy in all tissues examined, EDS microanalysis was used to confirm that these tissues contained elemental titanium and oxygen. The TEM micrographs and EDS spectra of the aggregates were compared with in vitro measurements of TiO2 nanoparticle injection solution (i.e., in water). The nanoparticles were also characterized using dynamic light scattering in water, 10 mM NaCl, and phosphate buffered saline (PBS). In low ionic strength solvents (water and 10 mM NaCl), the TiO2 particles had average hydrodynamic diameters ranging from 114-122 nm. In PBS, however, the average diameter increases to 1-2 microm, likely due to aggregation analogous to that observed in tissue by TEM and EDS. This investigation demonstrates the suitability of energy dispersive X-ray spectroscopy (EDS) for detection of nanoparticle aggregates in tissues and shows that disposition of TiO2 nanoparticles depends on the route of administration (i.v. or s.c.).

    See More

External Sources

  1. DOI: 10.1002/jat.1454
  2. PMID: 19626582

Library Notes

  1. Fiscal Year: FY2009-2010
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel