Skip NavigationSkip to Content

Comparison of planar, PET and well-counter measurements of total tumor radioactivity in a mouse xenograft model.

  1. Author:
    Green, Michael V
    Seidel, Jurgen
    Williams, Mark
    Wong, Karen J
    Ton, Anita
    Basuli, Falguni
    Choyke, Peter L
    Jagoda, Elaine M
  2. Author Address

    Molecular Imaging Program, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD; Contractor to Frederick National Laboratory for Cancer Research, Leidos Biomedical Research, Inc., Frederick, MD. Electronic address: greenmich@nih.gov., Molecular Imaging Program, Center for Cancer Research, National Cancer Institute, National Institutes of Health, Bethesda, MD., Imaging Probe Development Center, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD.,
    1. Year: 2017
    2. Date: Oct
    3. Epub Date: 2017 Jun 30
  1. Journal: Nuclear medicine and biology
    1. 53
    2. Pages: 29-36
  2. Type of Article: Article
  3. ISSN: 0969-8051
  1. Abstract:

    Quantitative small animal radionuclide imaging studies are often carried out with the intention of estimating the total radioactivity content of various tissues such as the radioactivity content of mouse xenograft tumors exposed to putative diagnostic or therapeutic agents. We show that for at least one specific application, positron projection imaging (PPI) and PET yield comparable estimates of absolute total tumor activity and that both of these estimates are highly correlated with direct well-counting of these same tumors. These findings further suggest that in this particular application, PPI is a far more efficient data acquisition and processing methodology than PET. Forty-one athymic mice were implanted with PC3 human prostate cancer cells transfected with prostate-specific membrane antigen (PSMA (+)) and one additional animal (for a total of 42) with a control blank vector (PSMA (-)). All animals were injected with [(18)F] DCFPyl, a ligand for PSMA, and imaged for total tumor radioactivity with PET and PPI. The tumors were then removed, assayed by well counting for total radioactivity and the values between these methods intercompared. PET, PPI and well-counter estimates of total tumor radioactivity were highly correlated (R(2)>0.98) with regression line slopes near unity (0.95< slope=1.02) and intercepts near zero (-0.001MBq=intercept =0.004MBq). Total mouse xenograft tumor radioactivity can be measured with PET or PPI with an accuracy comparable to well counting if certain experimental and pharmacokinetic conditions are met. In this particular application, PPI is significantly more efficient than PET in making these measurements. Copyright © 2017 Elsevier Inc. All rights reserved.

    See More

External Sources

  1. DOI: 10.1016/j.nucmedbio.2017.06.004
  2. PMID: 28797928
  3. WOS: 000412380600005

Library Notes

  1. Fiscal Year: FY2016-2017
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel