Skip NavigationSkip to Content

Characterization and analysis of thermal denaturation of antibodies by size exclusion high-performance liquid chromatography with quadruple detection

  1. Author:
    Hartmann, W. K.
    Saptharishi, N.
    Yang, X. Y.
    Mitra, G.
    Soman, G.
  2. Author Address

    Soman, G, SAIC Frederick Inc, Bioanalyt Dev Lab, Biopharmaceut Dev Program, Frederick, MD 21702 USA SAIC Frederick Inc, Bioanalyt Dev Lab, Biopharmaceut Dev Program, Frederick, MD 21702 USA.
    1. Year: 2004
  1. Journal: Analytical Biochemistry
    1. 325
    2. 2
    3. Pages: 227-239
  2. Type of Article: Article
  1. Abstract:

    Size exclusion chromatography (SEC) coupled with online light scattering, viscometry, refractometry, and UV-visible spectroscopy provides a very powerful tool for studying protein size, shape, and aggregation. This technique can be used to determine the molecular weight of the component peaks independent of the retention times in the SEC column and simultaneously measure the hydrodynamic radius and polydispersity of the protein. We applied this technology by coupling an Agilent Chernstation high-performance liquid chromatography system with a diode array UV-visible detector and a Viscotek 300 EZ Pro triple detector (combination of a light scattering detector, refractometer, and differential pressure viscometer) to characterize and compare the molecular properties of a number of monoclonal antibodies. Our studies reveal that different monoclonal immunoglobulin Gs (IgGs) and chimeric IgGs show slightly different retention times and therefore different molecular weights in gel filtration analysis. However, when they are analyzed by light scattering, refractometry, and viscometry, different IgGs have comparable molecular weight, molecular homogeneity (polydispersity), and size. Gel filtration coupled with UV or refractive index detection suggests that antibodies purified and formulated for preclinical and clinical development are more than 95% monomer with little or no detectable soluble aggregates. Light scattering measurements showed the presence of trace amounts of soluble aggregate in all the IgG preparations. The different IgG molecules showed different susceptibility to heat and pH. One of the murine antibodies was considerably less stable than the others at 55 degreesC. The application of this powerful technology for the characterization of monoclonal antibodies of therapeutic potential is discussed. (C) 2003 Elsevier Inc. All rights reserved

    See More

External Sources

  1. DOI: 10.1016/j.ab.2003.10.031
  2. WOS: 000188791200006

Library Notes

  1. No notes added.
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel