Skip NavigationSkip to Content

Quantitative measurement of endogenous estrogens and estrogen metabolites in human serum by liquid chromatography-tandem mass spectrometry

  1. Author:
    Xu, X.
    Roman, J. M.
    Issaq, H. J.
    Keefer, L. K.
    Veenstra, T. D.
    Zieger, R. G.
  2. Author Address

    SAIC Frederick Inc, NCI Frederick, Lab Proteom & Analyt Technol, Frederick, MD 21702 USA. SAIC Frederick Inc, NCI Frederick, Lab Comparat Carcinogenesis, Ctr Canc Res, Frederick, MD 21702 USA. NCI, Div Canc Epidemol & Genet, Epidemiol & Biostat Program, Bethesda, MD 20892 USA.;Veenstra, TD, SAIC Frederick Inc, NCI Frederick, Lab Proteom & Analyt Technol, POB B, Frederick, MD 21702 USA.;veenstrat@mail.nih.gov
    1. Year: 2007
    2. Date: Oct
  1. Journal: Analytical Chemistry
    1. 79
    2. 20
    3. Pages: 7813-7821
  2. Type of Article: Article
  3. ISSN: 0003-2700
  1. Abstract:

    Endogenous estrogen plays a key role in the development of human breast cancer, yet the contribution of specific estrogen metabolites and patterns of estrogen metabolism remains unclear. To determine their individual and joint roles in breast carcinogenesis, it is necessary to be able to measure quantitatively each estrogen metabolite in epidemiologic and clinical biospecimens. In this report, we detail a sensitive, specific, accurate, and precise high-performance liquid chromatography-tandem mass spectrometry method utilizing selected reaction monitoring for measuring the absolute quantities of free (unconjugated) and total (conjugated + unconjugated) endogenous estrogens and estrogen metabolites in human serum from premenopausal and postmenopausal women. The method requires a simple sample preparation and only 0.5 mL of serum, yet is capable of quantifying simultaneously 15 estrogens and estrogen metabolites (EM): estrone and its 2-, 4-, and 16 alpha-hydroxy and 2- and 4-methoxy derivatives; 2-hydroxyestrone-3-methyl ether; 17 beta-estradiol and its 2-hydroxy and 2- and 4-methoxy derivatives; and estriol, 17-epiestriol, 16-ketoestradiol, and 16-epiestriol. The lower limit of quantitation for each EM was 0.4 pg on-column, equivalent to 8 pg/mL (26.5-29.6 fmol/mL) in the original serum sample. Calibration curves were linear over a 10(3)-fold concentration range. For a stripped serum sample containing 8 pg/mL of each EM, accuracy (percent recovery of a known added amount) ranged from 91 to 113%. Intrabatch precision (including hydrolysis, extraction, and derivatization steps) ranged from 7 to 30% relative standard deviation (RSD), and interbatch precision ranged from 8 to 29% RSD. Since distinct roles have been proposed for many of these estrogen metabolites, an accurate, precise, sensitive, and specific method for measuring their levels in circulation should suggest new approaches to breast cancer prevention, screening, and treatment.

    See More

External Sources

  1. DOI: 10.1021/ac070494j
  2. WOS: 000250173200029

Library Notes

  1. No notes added.
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel