Skip NavigationSkip to Content

High-throughput single nucleotide polymorphism genotyping using nanofluidic Dynamic Arrays

  1. Author:
    Wang, J.
    Lin, M.
    Crenshaw, A.
    Hutchinson, A.
    Hicks, B.
    Yeager, M.
    Berndt, S.
    Huang, W. Y.
    Hayes, R. B.
    Chanock, S. J.
    Jones, R. C.
    Ramakrishnan, R.
  2. Author Address

    Wang, Jun, Lin, Min, Jones, Robert C.; Ramakrishnan, Ramesh] Fluidigm Corp, San Francisco, CA USA. [Crenshaw, Andrew, Hutchinson, Amy, Hicks, Belynda, Yeager, Meredith] NCI, Core Genotyping Facil, SAIC Frederick Inc, Adv Technol Program,FCRDC, Frederick, MD 21701 USA. [Crenshaw, Andrew, Hutchinson, Amy, Hicks, Belynda, Yeager, Meredith, Berndt, Sonja, Huang, Wen-Yi, Hayes, Richard B.; Chanock, Stephen J.] NCI, Div Canc Epidemiol & Genet, NIH, Bethesda, MD 20892 USA.
    1. Year: 2009
    2. Epub Date: 2009-11-28
  1. Journal: Bmc Genomics
    1. 10
  2. Type of Article: Article
  3. Article Number: 561
  4. ISSN: 1471-2164
  1. Abstract:

    Background: Single nucleotide polymorphisms (SNPs) have emerged as the genetic marker of choice for mapping disease loci and candidate gene association studies, because of their high density and relatively even distribution in the human genomes. There is a need for systems allowing medium multiplexing (ten to hundreds of SNPs) with high throughput, which can efficiently and cost-effectively generate genotypes for a very large sample set (thousands of individuals). Methods that are flexible, fast, accurate and cost-effective are urgently needed. This is also important for those who work on high throughput genotyping in non-model systems where off-the-shelf assays are not available and a flexible platform is needed. Results: We demonstrate the use of a nanofluidic Integrated Fluidic Circuit (IFC) - based genotyping system for medium-throughput multiplexing known as the Dynamic Array, by genotyping 994 individual human DNA samples on 47 different SNP assays, using nanoliter volumes of reagents. Call rates of greater than 99.5% and call accuracies of greater than 99.8% were achieved from our study, which demonstrates that this is a formidable genotyping platform. The experimental set up is very simple, with a time-to-result for each sample of about 3 hours. Conclusion: Our results demonstrate that the Dynamic Array is an excellent genotyping system for medium-throughput multiplexing (30-300 SNPs), which is simple to use and combines rapid throughput with excellent call rates, high concordance and low cost. The exceptional call rates and call accuracy obtained may be of particular interest to those working on validation and replication of genome-wide-association (GWA) studies.

    See More

External Sources

  1. DOI: 10.1186/1471-2164-10-561
  2. PMID: 19943955

Library Notes

  1. No notes added.
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel