Skip NavigationSkip to Content

Application of a Flow Cytometric Cytotoxicity Assay for Monitoring Cancer Vaccine Trials

  1. Author:
    Zaritskaya, L.
    Shafer-Weaver, K. A.
    Gregory, M. K.
    Strobl, S. L.
    Baseler, M.
    Malyguine, A.
  2. Author Address

    Zaritskaya, Liubov, Shafer-Weaver, Kimberly A.; Gregory, Melissa K.; Strobl, Susan L.; Baseler, Michael, Malyguine, Anatoli] SAIC Frederick Inc, Appl & Dev Res Support Program, Lab Cell Mediated Immunity, Frederick, MD 21702 USA.
    1. Year: 2009
  1. Journal: Journal of Immunotherapy
    1. 32
    2. 2
    3. Pages: 186-194
  2. Type of Article: Article
  1. Abstract:

    In this study, we evaluated the applicability of a flow cytometry-based cytotoxicity (FC) assay previously developed by our laboratory, for monitoring cancer vaccine trials. The assay simultaneously measures effector cell degranulation and target cell-death. Clinically relevant samples consisted of frozen peripheral blood mononuclear cells (PBMC) from vaccinated melanoma patients with known response to the melanoma peptide g209. Both PBMC and 7 day in vitro-stimulated lymphocyte from patient samples were used as effector cells in the FC assay. Activity against the relevant g209 and the control g280 peptide measured in the FC assay was directly compared with results obtained from the Granzyme B enzyme-linked immunosorbent spot assay and the standard Cr-51-release assay run in tandem. The FC assay detected low or no activity when PBMC were used as effector cells. Using cytotoxic T lymphocytes as effector cells, little or no effector cell degranulation or cytotoxicity was measured in the FC assay ill prevaccination samples. After vaccination, an increase in both degranulation and target cell death could be determined when target cells were pulsed with g209. No or low reactivity was found against g280 at any time point. Our findings exhibited excellent correlation between CD107a expression and GrB secretion and also Annexin V binding to target cells and specific lysis measured in the Cr-51-release assay. Results obtained from the FC assay were highly reproducible. Therefore, the FC assay may be applied to vaccine trial monitoring and allows the measurement of effector cell degranulation and target cell death simultaneously in a single sample.

    See More

External Sources

  1. PMID: 19238018

Library Notes

  1. No notes added.
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel