Skip NavigationSkip to Content

MONICA: a compact, portable dual gamma camera system for mouse whole-body imaging

  1. Author:
    Xi, W. Z.
    Seidel, J.
    Kakareka, J. W.
    Pohida, T. J.
    Milenic, D. E.
    Proffitt, J.
    Majewski, S.
    Weisenberger, A. G.
    Green, M. V.
    Choyke, P. L.
  2. Author Address

    [Xi, Wenze; Seidel, Jurgen; Green, Michael V.; Choyke, Peter L.] Natl Canc Inst, Mol Imaging Program, Ctr Canc Res, NIH, Bethesda, MD 20892 USA. [Xi, Wenze; Seidel, Jurgen; Green, Michael V.] Sci Applicat Int Corp, Frederick, MD USA. [Kakareka, John W.; Pohida, Thomas J.] NIH, Signal Proc & Instrumentat Sect, Div Computat Biosci, Ctr Informat Technol, Bethesda, MD 20892 USA. [Milenic, Diane E.] Natl Canc Inst, Radioimmune & Inorgan Chem Sect, Radiat Oncol Branch, Ctr Canc Res,NIH, Bethesda, MD 20892 USA. [Proffitt, James] Adapt IO Technol, Blacksburg, VA USA. [Majewski, Stan] W Virginia Univ, Dept Radiol, Morgantown, WV 26506 USA. [Weisenberger, Andrew G.] Thomas Jefferson Natl Accelerator Facil, Radiat Detectors & Imaging Grp, Newport News, VA USA.;Choyke, PL, Natl Canc Inst, Mol Imaging Program, Ctr Canc Res, NIH, Bethesda, MD 20892 USA.;pchoyke@mail.nih.gov
    1. Year: 2010
    2. Date: Apr
    3. Epub Date: 3/30/2010
  1. Journal: Nuclear Medicine and Biology
    1. 37
    2. 3
    3. Pages: 245-253
  2. Type of Article: Article
  3. ISSN: 0969-8051
  1. Abstract:

    Introduction: We describe a compact, portable dual-gamma camera system (named "MONICA" for MObile Nuclear Imaging CAmeras) for visualizing and analyzing the whole-body biodistribution of putative diagnostic and therapeutic single photon emitting radiotracers in animals the size of mice. Methods: Two identical, miniature pixelated Na(TI) gamma cameras were fabricated and installed "looking up" through the tabletop of a compact portable cart. Mice are placed directly on the tabletop for imaging. Camera imaging performance was evaluated with phantoms and field performance was evaluated in a weeklong In-111 imaging study performed in a mouse tumor xenograft model. Results: Tc-99m performance measurements, using a photopeak energy window of 140 keV +/- 10%, yielded the following results: spatial resolution (FWHM at 1 cm), 2.2 mm; sensitivity, 149 cps (counts per seconds)/MBq (5.5 cps/mu Ci); energy resolution (FWHM, full width at half maximum). 10.8%; count rate linearity (count rate vs. activity), r(2)=0.99 for 0-185 MBq (0-5 mCi) in the field of view (FOV); spatial uniformity, <3% count rate variation across the FOV. Tumor and whole-body distributions of the In-111 agent were well visualized in all animals in 5-min images acquired throughout the 168-h study period. Conclusion: Performance measurements indicate that MONICA is well suited to whole-body single photon mouse imaging. The field study suggests that inter-device communications and user-oriented interfaces included in the MONICA design facilitate use of the system in practice. We believe that MONICA may be particularly useful early in the (cancer) drug development cycle where basic whole-body biodistribution data can direct future development of the agent under study and where logistical factors, e.g., limited imaging space, portability and, potentially, cost are important. (C) 2010 Elsevier Inc. All rights reserved.

    See More

External Sources

  1. DOI: 10.1016/j.nucmedbio.2009.12.003
  2. PMID: 20346864
  3. PMCID: PMC2847584
  4. WOS: 000276551800002
  5. NIHMSID: Nihms165030

Library Notes

  1. Fiscal Year: FY2009-2010
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel