Skip NavigationSkip to Content

Photo- and Biophysical Studies of Lectin-Conjugated Fluorescent Nanoparticles Reduced Sensitivity in High Density Assays

  1. Author:
    Wang, Y. Q.
    Gildersleeve, J. C.
    Basu, A.
    Zimmt, M. B.
  2. Author Address

    [Wang, Yaqi; Basu, Amit; Zimmt, Matthew B.] Brown Univ, Dept Chem, Providence, RI 02912 USA. [Gildersleeve, Jeffrey C.] NCI, Biol Chem Lab, Ctr Canc Res, Frederick, MD 21702 USA.;Zimmt, MB, Brown Univ, Dept Chem, Providence, RI 02912 USA.
    1. Year: 2010
    2. Date: Nov
  1. Journal: Journal of Physical Chemistry B
    1. 114
    2. 45
    3. Pages: 14487-14494
  2. Type of Article: Article
  3. ISSN: 1520-6106
  1. Abstract:

    Lectin-conjugated, fluorescent silica nanoparticles (fNP) have been developed for carbohydrate-based histopathology evaluations of epithelial tissue biopsies The fNP platform was selected for its enhanced emissive brightness compared to direct dye labeling Carbohydrate microarray studies were performed to compare the carbohydrate selectivity of the mannose-recognizing lectin Concanavalin A (ConA) before and after conjugation to fluorescent silica nanoparticles (ConA-fNP) These studies revealed surprisingly low emission intensities upon staining with ConA-fNP compared to those with biotin-ConA/Cy3-streptavidin staining A series of photophysical and biophysical characterizations of the fNP and ConA-fNP conjugates were performed to probe the low sensitivity from fNP in the microarray assays Up to 1200 fluorescein (FL) and 80 tetramethylrhodamine (TR) dye molecules were incorporated into 46 nm diameter fNP, yielding emissive brightness values 400 and 35 times larger than the individual dye molecules, respectively ConA lectin conjugated to carboxylic acid surface-modified nanoparticles covers 15-30% of the fNP surface The CD spectra and mannose substrate selectivity of ConA conjugated to the fNP differed slightly compared to that of soluble ConA Although, the high emissive brightness of fNP enhances detection sensitivity for samples with low analyte densities, large fNP diameters limit fNP recruitment and binding to samples with high analyte densities The high analyte density and nearly two-dimensional target format of carbohydrate microarrays make probe size a critical parameter In this application, fNP labels afford minimal sensitivity advantage compared to direct dye labeling

    See More

External Sources

  1. DOI: 10.1021/jp101854m
  2. WOS: 000284018000045

Library Notes

  1. Fiscal Year: FY2010-2011
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel