Skip NavigationSkip to Content

How do I… facilitate a rapid response to a public health emergency requiring plasma collection with a public-private partnership?

  1. Author:
    Miller, Maureen J [ORCID]
    Skrzekut, Adam
    Kracalik, Ian [ORCID]
    Jones, Jefferson M [ORCID]
    Lofy, Kathryn H
    Konkle, Barbara A
    Haley, N Rebecca
    Duvenhage, Michael
    Bonnett, Tyler
    Holbrook, Michael
    Higgs, Elizabeth
    Basavaraju, Sridhar V [ORCID]
    Paranjape, Suman
  2. Author Address

    Epidemic Intelligence Service, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA., COVID-19 Response Team, U.S. Centers for Disease Control and Prevention, Atlanta, Georgia, USA., Bloodworks Northwest, Seattle, Washington, USA., Division of Healthcare Quality Promotion, Centers for Disease Control and Prevention, Atlanta, Georgia, USA., Washington State Department of Health, Tumwater, Washington, USA., Division of Clinical Research, National Institute of Allergy and Infectious Diseases, Rockville, Maryland, USA., Clinical Monitoring Research Program Directorate, Frederick National Laboratory for Cancer Research, Frederick, Maryland, USA., Division of Clinical Research, Integrated Research Facility, NIAID, Rockville, Maryland, USA.,
    1. Year: 2021
    2. Date: Sep 12
    3. Epub Date: 2021 Sep 12
  1. Journal: Transfusion
    1. 61
    2. 10
  2. Type of Article: Article
  3. ISSN: 0041-1132
  1. Abstract:

    In March 2020, there were no treatment options for COVID-19. Passive immune therapy including anti-SARS-CoV-2 hyperimmune globulin (hIVIG) was a logical candidate for COVID-19 therapeutic trials, given past success treating emerging pathogens with endogenous neutralizing antibodies. We established a plasma collection protocol for persons recovered from COVID-19. To speed recruitment in the first U.S. hotspot, Seattle, Washington, federal and state public health agencies collaborated with Bloodworks Northwest to collect convalescent plasma (CP) for manufacturing hIVIG. During March-December 2020, we identified and recruited prospective CP donors via letters to persons recovered from COVID-19 with laboratory-confirmed SARS-CoV-2 infection. Prospective donors were pre-screened and administered a medical history survey. Anti-SARS-CoV-2 neutralizing antibody (NAb) titers were classified as qualifying (=1:80) or non-qualifying (< 1:80) for enrollment based on a live virus neutralization assay. Generalized estimating equations were used to identify characteristics of donors associated with qualifying versus nonqualifying NAb titers. Overall, 21,359 letters resulted in 3207 inquiries, 2159 prescreenings with laboratory-confirmed SARS-CoV-2 infection, and 573 donors (27% of all pre-screenings with confirmed infection) who provided a screening plasma donation. Of 573 donors screened, 254 (44%) provided plasma with qualifying NAb titers, resulting in 1284?units for hIVIG manufacture. In a multivariable model, after adjusting for other factors, time (60?days) from COVID-19 symptom onset to screening was associated with lower odds of qualifying NAb (adjusted odds ratio = 0.67, 95% CI: 0.48-0.94). The collaboration facilitated a rapid response to develop and provide hIVIG for clinical trials and CP for transfusion. Only 1 in 12 donor inquiries resulted in a qualifying plasma donation. Challenges included recruitment and the relatively low percentage of persons with high NAb titers and limited screening capacity. This resource-intensive collaboration may not be scalable but informs preparedness and response strategies for plasma collection in future epidemics. Operational readiness plans with templates for screening, consent, and data collection forms are recommended. © 2021 AABB. This article has been contributed to by US Government employees and their work is in the public domain in the USA.

    See More

External Sources

  1. DOI: 10.1111/trf.16630
  2. PMID: 34510475
  3. WOS: 000695200400001

Library Notes

  1. Fiscal Year: FY2020-2021

Your Recently Viewed Publications:

TRPC Channels and Glioma
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel