Skip NavigationSkip to Content

Validation of a simplified HPV genotyping assay designed for cervical screening in low-resource settings

  1. Author:
    Desai, Kanan T
    Ajenifuja, Kayode O
    Adepiti, Clement A
    Inturrisi, Federica [ORCID]
    Dagnall,Casey
    Hoffman,Amanda
    Egemen, Didem
    Gage, Julia C
    Wentzensen, Nicolas
    de Sanjose, Silvia
    Schiffman, Mark
  2. Author Address

    National Cancer Institute, Rockville, Maryland, USA., Norwalk Hospital Internal Medicine Residency Program, Norwalk, Connecticut, USA., Obafemi Awolowo University, Ile-Ife, Osun, Nigeria., Cancer Genomics Research Laboratory, Frederick National Laboratory for Cancer Research, Leidos Biomedical Research, Inc., Frederick, Maryland, USA., ISGlobal, Barcelona, Catalonia, Spain.,
    1. Year: 2024
    2. Date: Dec 31
    3. Epub Date: 2024 12 31
  1. Journal: Journal of Clinical Microbiology
    1. Pages: e0163924
  2. Type of Article: Article
  3. Article Number: e0163924
  1. Abstract:

    Human papillomavirus (HPV) genotype predicts cervical cancer risk, and genotyping could help guide the management of HPV positives as part of cervical screening. An isothermal amplification HPV extended genotyping test (ScreenFire HPV RS assay) can assay up to 96 samples/controls in 1 hour plus preparation time. A novel format with pre-aliquoted reagents and an anti-contamination component (Zebra BioDome) could simplify the HPV testing process and reduce the chances of post-amplification contamination. We validated the Zebra BioDome formulation prior to its clinical use. Residual provider-collected cervical samples (n = 450) from a population-based study in rural Nigeria were retested with ScreenFire, once using the standard assay version (liquid reagents combined onsite) and twice with Zebra BioDome. HPV results with adequate DNA (N = 427) were analyzed channel-by-channel and using the cervical cancer risk-based hierarchy of HPV type channels (HPV16, else 18/45, else 31/33/35/52/58, else 39/51/56/59/68, else high-risk HPV negative) to evaluate Zebra BioDome repeatability and accuracy against the standard version. Zebra BioDome reduced the number of pipetting steps to run the ScreenFire HPV assay. Following amplification, the BioDome material formed a sealant layer above the reaction components. Zebra BioDome had excellent repeatability and agreement with the standard version, both at the channel-specific analysis (positive percent agreement between 88.4% [HPV39/51/56/59/68] and 100% [HPV16]; negative percent agreement between 97.8% [HPV31/33/35/52/58] and 100% [HPV39/51/56/59/68]) and hierarchical analysis (overall agreement 97.2%). The assay version utilizing Zebra BioDome performed similarly to the previously validated standard version of the ScreenFire HPV assay and is now undergoing field evaluation. This solution has the potential to reduce assay preparation time and risk of contamination, providing a simpler, low-cost, near-point-of-care HPV testing and extended genotyping solution for cervical screening in lower-resource settings. The potential application of Zebra BioDome technology to other PCR assays should be considered. This work validates a novel pre-packed formulation for the ScreenFire human papillomavirus (HPV) assay, which has the potential to simplify the HPV testing process and to reduce the chances of post-amplification contamination, providing a simpler, low-cost, near-point-of-care HPV testing, and extended genotyping solution for cervical screening in resource-limited settings as part of the ultimate public health goal to accelerate cervical cancer prevention. This technology can also have broad applications for other DNA amplification assays beyond HPV.

    See More

External Sources

  1. DOI: 10.1128/jcm.01639-24
  2. PMID: 39745462

Library Notes

  1. Fiscal Year: FY2024-2025
NCI at Frederick

You are leaving a government website.

This external link provides additional information that is consistent with the intended purpose of this site. The government cannot attest to the accuracy of a non-federal site.

Linking to a non-federal site does not constitute an endorsement by this institution or any of its employees of the sponsors or the information and products presented on the site. You will be subject to the destination site's privacy policy when you follow the link.

ContinueCancel